How to use veneer dryer scientifically?

2024/05/06 17:41

1. The veneer dryer has the relevant data (understood from the product description) in terms of the performance of the humidifier, especially in terms of the use of voltage standards and starting interval provisions, after starting for at least 3 minutes, the humidifier should not be started and stopped frequently, otherwise it is easy to damage the compressor; 2. The power supply of the humidifier should be provided through a dedicated line, and it is recommended that the leakage circuit breaker be manually restored in the power supply device 10A, which can not only protect the humidifier, but also prevent the personal risk caused by the power or fire risk caused by the leakage spark. 3. The humidifier can be moved and should be used in the rotating orientation; The orientation of the dehumidifier should be located in the center of the shell as far as possible to promote the air activity of the entire room to complete a more reasonable and uniform humidification; The orientation of the dehumidifier should be close to the goods, the import surface should face the goods, important goods or goods with certain humidity requirements should directly face the humidifier, the criteria for the placement of goods are important for secondary, from near to far;


veneer dryer


When moving the dehumidifier, the power should be disconnected, the movement must be straight, not placed horizontally, and prevent excessive vibration, after positioning should be placed smoothly, the movement should be at least 5 minutes after the humidifier is started; 5, there should be no obstacles in the inlet and outlet gas path, so as not to affect the activity of the air and reduce the humidification effect. The inlet and outlet should have as much space as possible, and the inlet and outlet should have a space of at least 1 meter, which is more conducive to the air activity of the whole room, and minimize the partial humidification phenomenon. 6. Check the intake filter regularly to prevent dust blocking and affecting the airflow. Usually clean the filter every 1 or 2 weeks. 7. Connect the drainpipe to the sewer or water container, and periodically check whether the drainpipe is blocked. In particular, if the water is filled in the water container, the water should be injected in a timely manner to prevent overflow of full water. 8, the doors and Windows of the wet room should be closed to prevent the outside humid air from entering, and it is necessary to consider moisture-proof measures in the room.

Place the dehumidifier away from the heating device and away from direct sunlight. 10, regular check whether the working system is normal, if there is abnormal noise, should be suspended maintenance, if the metal contact sound in operation, should immediately stop to check whether the fan impeller contact volute, drainage problems can be used again. 11. In special areas on special planes, such as temporary storage of designated patient areas, severe storage viewing, water overflow, rain engulfing and goods, should be handled in special areas on special planes, special machines should focus on humidification to prevent the impact of other goods; 12. When the room temperature is below 18 ° C and the relative humidity is less than 60%, the evaporator frosts, using the general type, and the auxiliary heating type should turn on the electric heater, and use heating to add the dew point temperature of the air to achieve the intention of useful humidification.